Description
Cover including emergency lighting kit for anti-panic areas (open area). Designed to clip onto Blade R body. 3 h autonomy with 12 h recharging time for maximum capacity. Self-test function. Test function via button on front, accessible when product is installed. Test function that can be activated via a Laser pointer. Built-in red/green LEDs for indicating different device states. Latest generation LiFePO4 (Lithium Iron Phosphate) 3.2 V, 3.2 Ah battery. Power in non-maintained mode: 0.22 W - Centralised on/off command module available on request for 150 or 250 luminaires (for this function further cabling with 2 conductors is required)
Dimensions
Diameter (mm) ø118
Technical performance
  • Class II

    Class II

  • Protected against penetration of solids larger than 12 mm, not protected against penetration of liquids.

    Protected against penetration of solids larger than 12 mm, not protected against penetration of liquids.

  • Protected against the penetration of solids larger than 1 mm, protected against the fall of water at a maximum angle of 15° <br /> On the visible part of the product once installed

    Protected against the penetration of solids larger than 1 mm, protected against the fall of water at a maximum angle of 15°
    On the visible part of the product once installed

Complies with EN60598-1 and pertinent regulations

Physical properties
Weight (kg) 0.2
Material Thermoplastic
Product certification
  • CE
    CE
  • EAC
    EAC
  • QCERT
    QCERT

Photometric data

Details

lm system
220
W system
3.6
Luminous efficiency - lm/W (system value)
61.11
lm in emergency mode
-
Maximum intensity (cd)
78
Total light flux at or above an angle of 90° (Lm)
0.09
Light output ratio (LOR)
100
Optic and beam angle
Optics for escape routes
Adjustability
fixed
Light colour quality
CRI 80
Colour temperature
5000 K
Lifetime LED 1
> 50,000h - L70 (Ta 25C)

Electrical data

Voltage 220 - 240
ZVEI code LED
Power Supply Electronic with inverter Control gear included
Mounting options Integral
Control DALI

Installation

Description

Clips onto Blade R body Ø170 mm. The control electronics and batteries can pass through the body of the device even when it is installed.;
Mounting Ceiling recessed
Wiring Cabling option: non-maintained(SE), requires 2 conductors (N/L). Cannot be used as a general lighting luminaire.
DALI monitoring