X785

Downloads

Colour

Technical Data

last update: 04/11/2025
Description
Kit for Citygrid Gateway installation on a local electrical cabinet, consisting of a rubber membrane and a 1.5 m long cable with an IP connector plus a safety locknut.
The Gateway (not included) is fixed to the electrical cabinet using 2 self-tapping screws (not included).
The cable supplied with this Kit is a 4 conductor cable, that both powers the Gateway and can be used for an eventual internal relay commanded by the Dashboard.
Dimensions
General (mm) 15x57x146
Technical performance
  • Protected against 5 J shocks

    Protected against 5 J shocks

Complies with EN60598-1 and pertinent regulations

Physical properties
Material Thermoplastic

Installation

Description

A hole must be drilled in the cabinet panel or internal fixing bracket to allow the cable and connector (that exit the rear of the Gateway) to pass through them.;
Wiring The Kit’s cable and connector must be connected to the 220-240 Vac electrical network via two conductors (L-N). A third conductor (mains power out) can be connected to a 230 Vac device with a maximum absorption of 1.0 A. We recommend connecting auxiliary command components to this output like relays/conductors.

Notes

Consult the cabinet manufacturer for more information about drilling and an eventual successive protection.