120B
Colour
Technical Data
last update: 30/10/2025Description
Fixed linear module with 10 reduced flow optic elements, specifically designed for continuous line connections with other (5 and/or 10 cell High Contrast Low Output) installed modules. Possibility of continuous contact with general light LED sticks. The module cannot be combined with other standard flow modules. Complete with adapter for installation on Superrail LV track. The adapter made of a thermoplastic material includes the DC/DC driver circuit with a DALI dimmable function. Integrated «Powerline» technology allows each light module on the track to be adjusted separately. Fixed optics with metallised thermoplastic high definition Opti-Beam reflectors. Main body made of extruded aluminium. A rapid tool-free system for connecting the adapter electrically and mechanically to the track.
Dimensions
General (mm)
179x22x45
Technical performance
Complies with EN60598-1 and pertinent regulations
Physical properties
Material
Extruded aluminium
Product certification
-
BIS -
BVB Byggvarube- dömningen -
CE -
UK Conformity Assessed
Photometric data
Details
lm system
913
W system
10.9
lm source
1100
W source
9.8
Luminous efficiency - lm/W (system value)
83.76
lm in emergency mode
-
Light output ratio (LOR)
83
Optic and beam angle
F - Flood 43°
Adjustability
fixed
Light colour quality
CRI (minimum) 90 - Rf (Colour Fidelity Index) 93 - Rg (Gamut Index) 99
Colour temperature
3500 K
MacAdam Step
2
Lifetime LED 1
> 50,000h - L90 - B10 (Ta 25C)
Electrical data
Voltage
48 V DC
ZVEI code
LED
Power Supply
Electronic Driver included
Mounting options
Integral
Dimmable option
Dimmable
Control
DALI
LED Current
0.35
Installation
Description
Mechanical fastening with adapter on track.;
Mounting
Low voltage track
Wiring
Integrated DC/DC LED driver in adapter - direct connection on 48V track. Track power supply unit to be ordered separately.
Notes
Reduced flow module for continuous line installation: this type of module can be combined with other installed modules and LED sticks, but it cannot be connected in a continuous line with other standard flow modules.