BM98
Colour
Optional accessories
Technical Data
last update: 07/11/2025Description
Direct light luminaire, designed to use monochrome LED lamps. Ground-, wall- and ceiling-recessed. Consists of a body and outer casing for installation, to be ordered separately. Extruded aluminium body, with die-cast aluminium end caps complete with silicone seals. Coated with liquid acrylic paint with a high level of weather and UV ray resistance. Lower PPS (polyphenylene sulfide) power box. The top of the optical assembly is closed by an 8 mm thick anti-slip glass screen (conforming to class R13 in accordance with DIN 51130), fixed with silicone. Complete with multi-LED power plate in Neutral White. Fitted with optics with plastic (methacrylate) lens for Flood lighting. The lower box has two PG11 nickel-plated brass cable glands for pass-through wiring, suitable for cables Ø6.5-11 mm. To fix the optical assembly to the outer casing the product has a quick coupling system using Allen keys. Outer casing for installation made of aluminium with technopolymer covers, to be ordered separately. All external screws used are made of A2 stainless steel. The luminaire technical characteristics conform to EN 60598-1 standards and particular requirements.
Dimensions
General (mm)
601x101x117
Technical performance
Complies with EN60598-1 and pertinent regulations
Physical properties
Material
Extruded aluminium
Product certification
-
BIS -
CE -
ENEC-03 -
QCERT -
UK Conformity Assessed
Photometric data
Details
lm system
1056
W system
18.2
lm source
2200
W source
16
Luminous efficiency - lm/W (system value)
58.02
lm in emergency mode
-
Light output ratio (LOR)
48
Optic and beam angle
F - Flood 42°
Adjustability
fixed
Light colour quality
CRI (minimum) 80 - Rf (Colour Fidelity Index) 86 - Rg (Gamut Index) 96
Colour temperature
4000 K
MacAdam Step
3
Lifetime LED 1
100,000h - L80 - B10 (Ta 25°C)
Lifetime LED 2
100,000h - L80 - B10 (Ta 40°C)
Charts and polar curves
Electrical data
Operating ambient temperature range
da -30°C a 50°C.
Voltage
220 - 240 AC
ZVEI code
LED
Power Supply
Electronic Control gear included
Mounting options
Integral
Installation
Description
Ground- and wall-recessed using the outer casing, to be ordered separately. For ground installation a drainage channel must be created or gravel inserted for drainage under the outer casing before installation, to guarantee the degree of protection stated.
For ceiling-mounting with plasterboard panels (1-30 mm thick), make the preparation openings as indicated in the instructions sheet and use the accessory with code 5926 (kit containing steel cables with reinforcement plates).;
Mounting
Wall recessed, Ceiling recessed, Ground recessed
Wiring
Equipped with electronic control gear 220-240V ac, 50/60Hz contained in the luminaire. For electrical connection the product has a lower box holding the terminal board (2-pin, max. 6mm2) and double cable glands for pass-through wiring.
Notes
Product complete with LED lamp. The frame, glass, optical assembly and outer casing together guarantee a maximum static load resistance of 1000 kg.