MJ51
Colour
Optional accessories
Technical Data
last update: 02/12/2025Description
direct emission modular lighting system with LED lamps. Initial module for general lighting (Low Contrast); can be used independently or in a continuous line. Minimal (frameless) version extruded aluminium double length profile; methacrylate opal screen set up for connection to end caps on both sides. Installation can be recessed, surface-mounted (ceiling/wall), or pendant. The module must be completed with the accessories kit needed for the selected type of installation. DALI dimmable electronic control gear integrated in the luminaire. Warm white high efficiency LED.
Dimensions
General (mm)
2394x32x75
Shape
Rectangular
Technical performance
Complies with EN60598-1 and pertinent regulations
Physical properties
Weight (kg)
4.2
Material
Aluminium and technopolymer
Product certification
-
BIS -
CCC S&E -
CE -
ENEC-03 -
QCERT -
UK Conformity Assessed
Photometric data
Details
lm system
3773.49
W system
38
lm source
4900
W source
32
Luminous efficiency - lm/W (system value)
99.3
lm in emergency mode
-
Light output ratio (LOR)
77
Optic and beam angle
GL - general lighting
Adjustability
fixed
Light colour quality
CRI (minimum) 80 - Rf (Colour Fidelity Index) 86 - Rg (Gamut Index) 96
Colour temperature
3000 K
MacAdam Step
3
Lifetime LED 1
50,000h - L80 - B10 (Ta 25°C)
Charts and polar curves
Electrical data
Inrush current
13.6 A / 304 µs
Voltage
230
ZVEI code
LED
Dimmable option
Dimmable
Control
DALI-2
Installation
Description
pendant: complete with power supply unit with cable (MWG5) and suspension cables (MWG6); surface-mounted: complete with supports (MWG7); recessed: after making the preparation slot, use the special supports to install in the false ceiling (MWG8).;
Mounting
Ceiling recessed, Ceiling surface, Ceiling pendant
Wiring
the module is fitted with 5-pin terminal blocks for pass-through wiring at the ends; the accessory power supply unit code MWG5 has a fixing plate with 5-pin terminal block for connection to the main power supply. DALI dimmable control gear integrated in the module.
Notes
initial modules may be completed with accessory end caps (MX80) and used independently in the various applications. To make continuous lines of lighting, use the intermediate modules. To correctly complete a continuous line, always use an initial module at the start or end of the structure.