Region and Language

Product standard

Your language

The North America market website will be available by November 2025. After clicking the 'Update' button, you will be redirected to the legacy version of the website. Le site Web du marché nord-américain sera disponible d'ici novembre 2025. Après avoir cliqué sur le bouton « Mettre à jour », vous serez redirigé vers le legacy version du site Web.
Update Update

MQ18

Downloads

Colour

Technical Data

last update: 21/10/2025
Description
LED lamp, ceiling-mounted luminaire; integrated electronic control gear, including an inverter and battery unit for permanent emergency light with 1.5 hours autonomy. Die-cast aluminium plate for surface mounting with diffuser element; technical, shaped aluminium sheet brackets for components and optics; multi-faceted reflector vacuum-metallised with aluminium vapours and finished with a protective anti-scratch layer; safety glass cover over LED lamp; lathe-shaped aluminium cylindrical body; lower ring in high resistance polycarbonate. General lighting optic.
Dimensions
Diameter (mm) ø240
Technical performance
  • Class I

    Class I

  • Protected against penetration of solids larger than 12 mm, protected against rain.

    Protected against penetration of solids larger than 12 mm, protected against rain.

Complies with EN60598-1 and pertinent regulations

Physical properties
Weight (kg) 3.75
Material Aluminium and technopolymer
Product certification
  • ENEC-03
    ENEC-03

Photometric data

Details

lm system
1776.29
W system
13.3
lm source
2090
W source
11
Luminous efficiency - lm/W (system value)
133.56
lm in emergency mode
-
Light output ratio (LOR)
85
Optic and beam angle
GL - general lighting
Adjustability
fixed
Light colour quality
CRI (minimum) 80 - Rf (Colour Fidelity Index) 83 - Rg (Gamut Index) 94
Colour temperature
4000 K
MacAdam Step
2
Lifetime LED 1
> 50,000h - L80 - B10 (Ta 25°C)

Charts and polar curves

Electrical data

Voltage 220 - 240
ZVEI code LED
Power Supply Electronic with inverter Driver included
Mounting options Integral

Installation

Description

Plate fixed to ceiling using screws and screw anchors (not included); bayonet assembly systems ensuring simple installation and maintenance; snap-on spring fastening for reflector. Wall or pendant application option available thanks to special accessory kits with a separate code.;
Mounting Wall surface, Ceiling surface, Ceiling pendant
Wiring Control gear integrated in luminaire; mains and optic unit connections made with quick coupling terminal blocks.

Notes

Kit for wall-mounting: code no. 9443 - kit for steel cable pendant system L 1500: code no. 9442