The North America market website will be available by November 2025. After clicking the 'Update' button, you will be redirected to the legacy version of the website. Le site Web du marché nord-américain sera disponible d'ici novembre 2025. Après avoir cliqué sur le bouton « Mettre à jour », vous serez redirigé vers le legacy version du site Web.
Update Update

Q419

Downloads

Colour

Technical Data

last update: 08/11/2025
Description
LED module set up for housing in initial or intermediate system profiles - up + down emission. DALI dimmable electronic control gear integrated in the luminaire. Extruded aluminium heat sink; high emission yield flux enhancer. Warm LED.
Dimensions
General (mm) 1196
Technical performance
  • Class I

    Class I

  • Protected against penetration of solids larger than 12 mm, not protected against penetration of liquids.

    Protected against penetration of solids larger than 12 mm, not protected against penetration of liquids.

Complies with EN60598-1 and pertinent regulations

Physical properties
Material Aluminium and technopolymer
Product certification
  • BIS
    BIS
  • CCC S&E
    CCC S&E
  • CE
    CE
  • NOM
    NOM
  • QCERT
    QCERT
  • UK Conformity Assessed
    UK Conformity Assessed

Photometric data

Details

lm system
5134
W system
50.7
lm source
7550
W source
45
Luminous efficiency - lm/W (system value)
101.26
lm in emergency mode
-
Total light flux at or above an angle of 90° (Lm)
1454
Light output ratio (LOR)
68
Optic and beam angle
GL - general lighting
Adjustability
fixed
Light colour quality
CRI (minimum) 80 - Rf (Colour Fidelity Index) 86 - Rg (Gamut Index) 96
Colour temperature
3000 K
MacAdam Step
3
Lifetime LED 1
> 50,000h - L90 - B10 (Ta 25°C)

Electrical data

Voltage 220 - 240
ZVEI code LED
Power Supply Electronic Driver included
Mounting options Integral
Dimmable option Dimmable
Control DALI-2

Installation

Description

Module insertion on profiles facilitated by a quick coupling system.;
Wiring Quick coupling terminal block connection to simplify connections between the luminaires. LED module complete with integrated control gear.