The North America market website will be available by November 2025. After clicking the 'Update' button, you will be redirected to the legacy version of the website. Le site Web du marché nord-américain sera disponible d'ici novembre 2025. Après avoir cliqué sur le bouton « Mettre à jour », vous serez redirigé vers le legacy version du site Web.
Update Update

QB02

Downloads

Colour

Technical Data

last update: 08/11/2025
Description
Angular element for Frame version profiles with contact frame; including a 3000K Warm LED module, Low Output version. Methacrylate opal screen for diffused general light; screen set up for overlap connections. Integrated control gear. Pass-through wiring for continuous lines:
Dimensions
General (mm) 658x658x75
Technical performance
  • Class I

    Class I

  • Protected against penetration of solids larger than 12 mm, not protected against penetration of liquids.

    Protected against penetration of solids larger than 12 mm, not protected against penetration of liquids.

Complies with EN60598-1 and pertinent regulations

Physical properties
Weight (kg) 4.17
Material Extruded aluminium
Product certification
  • BIS
    BIS
  • CE
    CE
  • ENEC-03
    ENEC-03
  • NOM
    NOM
  • QCERT
    QCERT

Photometric data

Details

lm system
1900
W system
17.1
lm source
1250
W source
7.5
Luminous efficiency - lm/W (system value)
111.11
lm in emergency mode
-
Light output ratio (LOR)
76
Optic and beam angle
GL - general lighting
Adjustability
fixed
Light colour quality
CRI (minimum) 80 - Rf (Colour Fidelity Index) 86 - Rg (Gamut Index) 96
Colour temperature
3000 K
MacAdam Step
3
Lifetime LED 1
> 50,000h - L90 - B10 (Ta 25°C)

Charts and polar curves

Electrical data

ZVEI code LED
Power Supply Electronic Driver included
Mounting options Integral

Installation

Description

Recessed using the brackets on the profile.;
Mounting Ceiling recessed
Wiring The angular profile is supplied with pass-through wiring for continuous lines. Quick coupling terminal blocks to simplify connections between the luminaires. Complete with integrated ON-OFF - non-dimmable control gear.

Notes

Take care when configuring the system; to complete a continuous line with an angular profile correctly, two initial modules are required, one for each end of the corner.