SS91
Colour
Optional accessories
Technical Data
last update: 04/12/2025Description
Luminaire for walkways designed to use LED lamps with a high efficiency value. Ceiling, wall-recessed and pole-mounted installation. It consists of an optical assembly with an IP66 protection rating and an outer casing or wall-mounted base to be ordered separately. The optical assembly and base are made of aluminium alloy treated with powder paint, which provides a high level of resistance to weather and UV rays. Plastic closure guard at the rear of the optical assembly. Complete with plastic cable gland and outlet cable. Transparent sodium-calcium tempered safety glass Luminaire with no visible screws and an anti-vandal system that uses an opening key to access the rear wiring compartment (supplied in the package). All external screws used are made of A2 stainless steel.
Dimensions
General (mm)
180x180x45
Technical performance
Complies with EN60598-1 and pertinent regulations
Physical properties
Weight (kg)
0.74
Material
Aluminium
Product certification
-
BIS -
CE -
QCERT -
UK Conformity Assessed
Photometric data
Details
lm system
506
W system
5.8
lm source
1100
W source
4.8
Luminous efficiency - lm/W (system value)
87.24
lm in emergency mode
-
Total light flux at or above an angle of 90° (Lm)
10
Light output ratio (LOR)
46
Optic and beam angle
AL - Longitudinal asymmetric optic
Adjustability
fixed
Light colour quality
CRI (minimum) 80 - Rf (Colour Fidelity Index) 85 - Rg (Gamut Index) 99
Colour temperature
3000 K
MacAdam Step
3
Lifetime LED 1
100,000h - L90 - B10 (Ta 25°C)
Lifetime LED 2
100,000h - L80 - B10 (Ta 40°C)
Charts and polar curves
Electrical data
Operating ambient temperature range
da -20°C a 50°C.
Voltage
220 - 240 AC
ZVEI code
LED
Power Supply
Electronic Power supply included
Mounting options
Integral
Control
On/off
Installation
Description
Wall-recessed installation with a plastic outer casing to be ordered separately. Disposable polystyrene formwork for creating the outer casing housings for installations in concrete walls that are then plastered or finished with bricks so the end surface is flush with the optical assembly. Wall-mounted installation requires an aluminium base to be ordered separately. Pole-mounted installation requires a pole to be ordered separately.;