X784
Colour
Technical Data
last update: 04/11/2025Description
Kit for Citygrid Gateway installation on local electrical cabinet, consisting of a rubber membrane and a 1.5 m long cable with an IP connector plus a safety locknut.
The Gateway (not included) is fixed to the electrical cabinet using 2 self-tapping screws (not included).
The cable supplied with this Kit is a 2 conductor cable, that powers the Gateway and therefore does not allow an internal relay to be used.
The Gateway (not included) is fixed to the electrical cabinet using 2 self-tapping screws (not included).
The cable supplied with this Kit is a 2 conductor cable, that powers the Gateway and therefore does not allow an internal relay to be used.
Dimensions
General (mm)
15x57x146
Technical performance
Complies with EN60598-1 and pertinent regulations
Physical properties
Material
Thermoplastic
Installation
Description
A hole must be drilled in the cabinet panel or internal fixing bracket to allow the cable and connector (that exit the rear of the Gateway) to pass through.;
Wiring
The Kit’s cable and connector must be connected to the 220-240 Vac electrical network via two conductors (L-N).
Notes
Consult the cabinet manufacturer for more information about drilling and an eventual successive protection.