Region and Language

Product standard

Your language

3036

Downloads Downloads

Colour

Technical Data

last update: 25/08/2026
Description
Suspended fitting for direct/indirect emission designed for compact fluorescent lamps TC-L. Controlled luminance L = 1000 cd/m² a > 65°. Suitable for application in environments where VDUs are used - according to standard EN 12464-1. Distribution of the luminous flow: 90% indirect light, 10% direct light. The optical assembly has painted extruded-aluminium side profiles, painted injection-moulded polycarbonate end caps and an internal painted sheet-steel structure. The drawn-aluminium-sheet microperforated reflector permits excellent diffusion of the direct component of the light, if combined with a diffusing polycarbonate film. The fitting comes complete with transparent power supply cable and steel suspension cables (length 2 m), with millimetric adjustment system on the optical assembly. The fitting is mounted to the ceiling by means of steel plates covered by injection-moulded polycarbonate bases. The terminal blocks housed inside either base make it possible to have double operation.
Dimensions
General (mm) 620x405x62
Technical performance
  • Class I

    Class I

  • Protected against penetration of solids larger than 12 mm, not protected against penetration of liquids.

    Protected against penetration of solids larger than 12 mm, not protected against penetration of liquids.

Complies with EN60598-1 and pertinent regulations

Physical properties
Material Aluminium

Photometric data

Details

W source
55
lm in emergency mode
-
Maximum intensity (cd)
614
Total light flux at or above an angle of 90° (Lm)
12013.86
Light output ratio (LOR)
65
Adjustability
fixed

Electrical data

Voltage
220-240 VAC
ZVEI code
TC-L
Power Supply
Electronic Control gear included
Mounting options
Integral

Installation

Description

Suspended by means of steel cables. The fitting has a 2-m long electric cable.;
Mounting Ceiling pendant
Wiring Electronic control gear designed for operation 50% and 100%. The electronic components needed for operation are housed into the internal structure and are covered by a sheet-steel protection plate.
Subscribe