Region and Language

Product standard

Your language

MM44

Downloads Downloads

Colour

Technical Data

last update: 25/08/2026
Description
Ceiling-mounted luminaire, designed to use T16 linear fluorescent lamps. Optical assembly with painted, extruded aluminium lateral profiles, plastic end caps. Optical assembly consists of super-pure aluminium reflectors. The methacrylate diffuser screen has microprisms and, combined with a milky polycarbonate diffuser film, allows optimum diffusion of the direct light and luminance control L<1,500 cd/m2 for α≥65° (35W). Luminaire suitable for use in environments with video terminals in accordance with EN 12464-1. Ceiling-mounted version complete with plate for fitting on ceiling and anti-fall safety cables.
Dimensions
General (mm) 1500x300x50
Technical performance
  • Class I

    Class I

  • Protected against the penetration of solids larger than 1 mm, not protected against penetration of liquids.

    Protected against the penetration of solids larger than 1 mm, not protected against penetration of liquids.

Complies with EN60598-1 and pertinent regulations

Physical properties
Material Aluminium

Photometric data

Details

W source
35
lm in emergency mode
-
Maximum intensity (cd)
871
Total light flux at or above an angle of 90° (Lm)
0
Light output ratio (LOR)
50
Optic and beam angle
UGR - Luminance control UGR<19
Adjustability
fixed

Charts and polar curves

Electrical data

Supply voltage
220-240 VAC
ZVEI code
T 16
Power Supply
Electronic with inverter Control gear included
Mounting options
Integral

Installation

Description

Ceiling-mounted using a plate which can be applied to the ceiling, complete with anti-fall system cables.
Mounting Ceiling surface
Wiring Electronic control gear set up for emergency light, complete with inverter and rechargeable battery unit. Terminal blocks set up for REST MODE. Permanent emergency light; 1.5 hours autonomy with 12 hour recharging cycle - 3 hours autonomy with 24 hour recharging cycle. Conforms to EN60598-2-22.