Region and Language

Product standard

Your language

X783

Downloads Downloads

Colour

Technical Data

last update: 06/08/2026
Description
Kit for Citygrid Gateway pole-installation consisting of a plastic base that is concave on one side and an 8 m long cable with an IP connector plus a safety locknut. The Gateway (not included) is fixed to the base supplied in the Kit using 2 self-tapping screws (included). The cable supplied with this Kit is a 2 conductor cable, that powers the Gateway and therefore does not allow an internal relay to be used.
Dimensions
General (mm) 15x57x146
Technical performance
  • IK08 - Protected against 5 J shocks

    IK08 - Protected against 5 J shocks

Complies with EN60598-1 and pertinent regulations

Physical properties
Material Thermoplastic

Installation

Description

The base is fixed to the pole using 2 self-tapping screws (not included). A hole must be drilled in the pole to allow the cable and connector (that exit the rear of the Gateway) to pass through it.
Wiring The Kit’s cable and connector must be connected to the 220-240 Vac electrical network via two conductors (L-N).

Notes

Consult the pole manufacturer for more information about drilling and an eventual successive protection.

Additional Information

Description

Available, at the moment, for the European market only.
Subscribe