SV46
Colour
Optional components
Technical Data
last update: 06/11/2026Description
Square LED panel with monochromatic light source, designed for lay-in installation in modular false ceilings. The optical compartment consists of a white painted steel sheet frame, a microprismatic frosted methacrylate diffuser screen that ensures an emission compliant with UGR<19 and L<3000 cd/m² requirements, and a rear sheet metal closing bottom.
The LEDs are positioned on the back of the lighting fixture, while the electronic driver is housed in the upper part of the product. The connection between the driver and the lighting fixture is made via a quick-connection system, which does not require the use of tools.
Fixture complete with integrated DALI-2 sensor, with lux and motion detector.
Integrated sensor specifications:
- Illuminance dynamic range: 1 - 2000 lx.
- Motion detection angle 84°.
- Light measurement detection angle 30° - 60° (asymmetric). Supplied with an accessory shutter that prevents detection from a specific direction, which can be installed if necessary.
- Power supply from the DALI line of the connected system (consumption 9 mA).
For movement and/or daylight control operation, the fixture must be connected to a DALI-2 system/application controller and be programmed for this purpose. Contact iGuzzini for systems compatible with the integrated DALI-2 sensor.
Dimensions
General (mm)
595x595
Technical performance
Complies with EN60598-1 and pertinent regulations
Physical properties
Weight (kg)
2
Product certification
-
ENEC pending
Photometric data
Details
lm system
4200
W system
27.7
lm source
W source
Luminous efficiency - lm/W (system value)
151.62
lm in emergency mode
-
Maximum intensity (cd)
1924
Total light flux at or above an angle of 90° (lm)
0
Light output ratio (LOR)
100
Optic and beam angle
UGR Down
Adjustability
fixed
Light colour quality
CRI 92 - Rf (Colour Fidelity Index) 90 - Rg (Gamut Index) 99
Colour temperature
3000 K
MacAdam Step
3
Lifetime LED 1
>50,000h - L90 - B10 (Ta 25°C)
Lifetime LED 2
Electrical data
Operating ambient temperature range (C°)
from -20°C to +35°C. (*)
ZVEI code
LED
Power Supply
Electronic Power supply included
Mounting options
Integral
Control
DALI-2 sensor
Installation
Description
Recessed: on plasterboard false ceilings using dedicated springs (to be ordered separately).
Surface mounted: via installation frame (to be ordered separately).
Suspension: via power supply kit and suspension accessories (to be ordered separately).
Mounting height min 2.4 m / max 4 m for movement and max 3 m as lux + motion sensor. Refer to the instruction sheet for permitted positions. Example of movement coverage surface diameter: 4.3 m @ 2.4 m installation h.;
Mounting
Ceiling recessed, Ceiling surface, Ceiling pendant
Wiring
Power line and DALI line
Notes
DALI EN 62386-101 ed.2. The sensor used is DALI-2 certified parts 101, 103, 301, 303, 304.
Occupancy sensor DALI part 303: instance 0
Light sensor DALI part 304: instance 1